Why a record was not picked up
What to check when an order, purchase order or other record has no event at all in the Control Panel, and how to get it through.
The short answer
If you search the Control Panel for a record and find no event for it, the stream never picked it up, so there is nothing to resend. This is different from a failed event. A stream only collects the records that match its source settings at the moment it runs. The usual reasons a record is missed are that it fell outside the stream's date window, it did not match a filter, it was already marked as sent, the stream did not run, or a webhook never reached HC.
First, confirm there really is no event
In the Control Panel, go to Reporting > Events.
Search for the record using the reference the source system uses. An order can carry a different number in each system, so try the source system's ID as well as the name you normally use.
Widen the date filter to cover the day the record was created and the days after it.
If you find an event, this page is not the one you need:
Error or Failed: the record was picked up but could not be delivered. See How to fix and resend a failed event.
Aborted: HC stopped the event on purpose, usually because the record had already been sent. See Event status definitions.
Why a record is missed
It fell outside the stream's date window
Most scheduled streams only ask the source system for recent records, for example those created or changed in the last 24 hours or the last few days. This window is often called the lookback. A record older than the window is not collected, even if nothing else is wrong with it.
The most common way this happens is a knock-on delay. An order fails to reach your ERP, the failure is fixed several days later, and by then the order is too old for the next stream in the chain, such as the one that sends orders from the ERP to the warehouse. The order now exists in the ERP but the warehouse stream never sees it. Fixing failed events quickly is the best way to prevent this.
It did not match a source filter
Streams are set up to collect only the records your business wants to send. Depending on your integration, a filter can exclude records by status, payment state, tag, country, location, order number prefix or cancellation. A record that does not match is skipped at the source and no event is created for it. An unpaid order on a stream that only collects paid orders is a typical example.
It was already marked as sent
To avoid sending the same record twice, many streams mark each record in the source system once it has been collected, using a checkbox field or a tag, and then ignore anything already marked. If the mark is set by mistake, the stream treats the record as done. This often happens when a record is created by copying an older one, because the copy inherits the mark. The exact field or tag varies by organisation.
Clearing the mark makes the record eligible again, but only if it is still inside the stream's date window.
The stream did not run
A stream with a manual trigger does nothing until someone runs it. A stream that has been paused, or whose job failed before it created any events, also collects nothing for that period. Go to Reporting > Jobs and check whether the stream ran around the time you expected, and whether the job finished.
A webhook never arrived
Some streams do not ask the source system for records. They wait for the source system to send a webhook (a message sent automatically when something happens). If the source system does not send it, because of an outage on its side or because the record was created in a way that does not trigger one, HC has no record of it at all. HC cannot re-request a webhook that was never sent. Check the source system's own status and webhook history, or ask its support team.
No stream covers that kind of record
If the record is of a type, sales channel or location your integration was never set up to handle, no stream is looking for it. That is a change to your integration, not a fault.
Getting the record through
Fix the cause first: correct the status or missing data in the source system, or clear the mark that says the record was already sent.
If the record is still inside the stream's date window, wait for the next scheduled run or run the stream yourself. See Running a stream manually. Manual runs are not available on webhook-triggered streams.
If the record is older than the window, the stream needs to run once with a wider window. Any change made to the source settings for that run must be reversed afterwards, or every later run will collect more than it should. If you are not sure how your stream's window is set, contact HC.
Check Reporting > Events again. You should now see an event for the record with the status Ok.
What to send HC if you are still stuck
The stream name.
The record's reference in the source system, and the date and time it was created.
What you have already checked from the list above.
See How to get support.